CIPP

On this page we publish interesting articles concerning CIPP in English. As we are a national association, our focus is mainly on the German market. But this may change soon. Stay with us and leave your E-Mail address at the end of the page.

CIPP Test Laboraties

Tender Texts for CIPP Tests

Quality assurance as part of site supervision CIPP (main drive)

Standard tests

Testing of short-time bending stress, determination of short-time e modulus and wall thickness in 3-point bending test according to DIN EN ISO 178 (in conjunction with DIN EN ISO 11296-4) 5 individual tests per specimen,  according to section 7.2.2 of DWA-A 143-3

Testing the water tightness of the laminate Based on DIN EN 1610 at 0.5 bar negative pressure, test time 30 min according to section 7.2.9 of DWA-A 143-3

Additional tests

Determination of the glass/resin ratio by calcination method (determination of ash residue) according to DIN EN ISO 1172 according to section 7.2.8 of DWA-A 143-3

Determination of the 24h e modulus, determination of the creep tendency according to DIN EN ISO 899-2 in connection with short-term value (DIN EN ISO 178 / DIN EN ISO 11296-4) according to section 7.2.4 of DWA-A 143-3

Testing of residual styrene content in laminate samples for pipes in water protection areas according to DIN 53394-2 according to section 7.2.5 of DWA-A 143-3

Checking the conformity of the reaction resins used by FT-IR spectral analysis according to ASTM D5576 according to section 7.2.7 of DWA-A 143-3

Determination of the ring stiffness and the circumferential e modulus in the short-time crushing test according to DIN EN 1228 / ISO 7685

 

Quality assurance as part of site supervision CIPP (lateral drive)

Check of the curing of the laminate (for EP resins): DSC analysis (DDK measurement) according to DIN EN ISO 11357-2 including visual assessment of the laminate and determination of the wall thickness according to annex F of DWA-A 143-3

Check of the curing of the laminate (for UP resins): Determination of the residual styrene content according to DIN 53394-2 (GC) including visual assessment of the laminate and determination of the wall thickness

Determination of the e modulus on small samples: DMA analysis (dynamic mechanical analysis) according to ISO 6721, part 4, according to annex F of DWA-A 143-3

Site sample (main drive)

> DN 200: Radial length: dependent of wall thickness (20 times), Axial length: min. 350 mm

< DN 200: as round pipe section

Site-Sample (lateral drive)

Cored hole 3-5 cm (for DDK and DMA test)